top of page
RV9E
Exploitation routière et électrique | Reefer

The RV9E Road operation and Electric Standby reefer unit is designed to deliver reliable performance for fresh or frozen applications on low to medium roof vans.

A direct driven engine-mounted compressor provides superior cooling, performance and guaranteed affordability.

RV9E Reefer
Standard | Caractéristiques

  • Valve de protection pour compresseur CPR (R404a)

  • Séparateur d'huile pour compresseur → Durée de vie prolongée

  • Dégivrage par gaz chaud

  • Échangeur mince (Slim line) → Espace de chargement maximal

  • Contrôle de température en cabine simple (°C / °F)
    Conception légère 

  • High BTU cooling capacity 9,100 BTU

  • R404a freezer refrigerant 

  • R452a refrigerant compatible

  • VALEO  Road compressor

  • Heavy Duty SANDEN standby compressor 

  • High air flow evaporator cooling fans

  • Warranty 3 Year parts and labor

Performances | Qualité | Durabilité | Faible coût de service | Meilleur prix
RV9E Reefer
Twin Fan Evap
Installation | Caractéristiques de conception
Temperature Guide:
Cooling Mode
BTU
Watts
Electric Cooling 35°F (2°C)
5200
1550
Electric Cooling 0°F (-18°C)
3400
995
Road Cooling 35°F (2°C)
7800
2285
Road Cooling 0°F (-18°C)
3410
1000
Components:
Specifications
Value
Standby Voltage
115V (20A)
AMP Draw (12VDC/AC)
29A (16A)
Evaporator Dimension
33" x 22" x 7" (840mm x 555mm x 180mm)
Condenser Dimension
33" x 23" x 9.5" (840mm x 585mm x 241mm)
Refrigerant Charge
3.1LB (1.4KG)
Refrigerant
R404a (R452A)
Defrost
Hot Gas
Compressor
TM15 - TM15
Airflow CFM
765
Vehicle Application
Low Roof
Evaporator Weight
49LB (22KG)
Condenser Weight
140LB (64KG)

*Ambient 100°F (38°C)

*Assume min. 3" of insulation for 35°F (2°C) and min. 4" of insulation for 0°F (-18°C) with added polar walls

Reefer Operation - TIPS & HINTS 

 

  • Pre-chill the cargo area for 15 minutes before loading on very hot days.

  • Switch the reefer unit off while loading product into cargo area.

  • Minimize the length of time that doors are open when delivering.

  • Product should be stored at the correct temperature before loading.

  • Do not block the evaporator air intake or outlets.

  • Allow space around all sides of the load for air circulation.

  • Check the load temperature regularly.

  • When using power standby check that the mains power supply is suitably rated to power the reefer unit.

  • Switch the vehicle engine off and cab control off before connecting mains power.

  • Avoid using additional extension leads on electric standby. Maximum length of cable 25 feet.

bottom of page