The RVT Reefer unit is designed for vans, truck bodies up to 22 ft, or compartmental applications.

 

It uses an engine-mounted compressor and provides superior cooling, performance and guaranteed affordability.

RVT Condenser.png
Standard | Features 
  • CPR Compressor protection valve 

  • Compressor oil separator - Extended service life

  • Hot gas defrost  

  • Slim line cooler - Maximum cargo space

  • Simple operation temperature cab controller (°C /°F) 

  • Lightweight in design

  • High BTU cooling capacity 18,300 BTU

  • R404a freezer refrigerant  

  • VALEO  Road compressor 

  • Optional 230VAC 1 Phase Heavy duty Scroll standby compressor | Separate POD Design

  • High air flow evaporator cooling fans

  • 3 Years Warranty in parts and labor

  • R452a refrigerant compatible

R452A-Refrigerant-Gas-Dubai-fotor-20240629135232.png
RVT Reefer Van_edited.jpg
Performance | Quality | Durability | Low Service Cost | Best Price
RVT Condenser Section
RVT Evaporator
RVT Condenser Front
RVT Evaporator #2
RVT - Remote 230v Standby Module
RVT Reefer Truck
RVT | Specifications
Temperature Guide:
Cooling Mode
BTU
Watts
Road Cooling 0°F (-18°C)
9500
2785
Road Cooling 35°F (2°C)
20500
6000
Components:
Specifications
Value
Condenser Weight
132LB (59.8 KG)
Evaporator Weight
85 LB (38 KG)
Vehicle Application
Truck > 24
Airflow CFM
1600
Compressor
TM21
Defrost
Hot Gas
Refrigerant
R404a (R452A)
Refrigerant Charge
7.7 LB (3.5 KG)
Condenser Dimension
55.5" x 21" x 20" (1409 x 533 x 508mm)
Evaporator Dimension
53" x 24" x 9" (1345 x 609 x 228mm)
AMP Draw (12VDC/AC)
45A

*Assume min. 3" of insulation for 35°F (2°C) and min. 4" of insulation for 0°F (-18°C) with added polar walls

Reefer Operation - TIPS & HINTS 

 

  • Pre-chill the cargo area for 15 minutes before loading on very hot days.

  • Switch the reefer unit off while loading product into cargo area.

  • Minimize the length of time that doors are open when delivering.

  • Product should be stored at the correct temperature before loading.

  • Do not block the evaporator air intake or outlets.

  • Allow space around all sides of the load for air circulation.

  • Check the load temperature regularly.

  • When using power standby check that the mains power supply is suitably rated to power the reefer unit.

  • Switch the vehicle engine off and cab control off before connecting mains power.

  • Avoid using additional extension leads on electric standby. Maximum length of cable 25 feet.